JobIntegradorAssimService.ProcessarIntegracao

The job is finished. It will be removed automatically 10/10/2026 22:15:45.
// Id: #10122034
using Inpart.Integracao.GerenciadorJobs.Services;

var jobIntegradorAssimService = Activate<JobIntegradorAssimService>();
await jobIntegradorAssimService.ProcessarIntegracao();

Parameters

CurrentCulture
""
RecurringJobId
"integrador-assim-criaopme"
RetryCount
1
Time
1791584110

State

10/09/2026 22:15:45 (+ <1ms) Deleted

Exceeded the maximum number of retry attempts.

System.Exception

An error occurred while reading a database value for property 'NFItem.CdStatus'. The expected type was 'System.Int16' but the actual value was of type 'System.Byte'.

+1.344s Failed

An exception occurred during performance of the job.

System.Exception (fe68b61060a9.staging:1)

An error occurred while reading a database value for property 'NFItem.CdStatus'. The expected type was 'System.Int16' but the actual value was of type 'System.Byte'.

System.Exception: An error occurred while reading a database value for property 'NFItem.CdStatus'. The expected type was 'System.Int16' but the actual value was of type 'System.Byte'.
   at Inpart.Integracao.GerenciadorJobs.Services.JobIntegradorAssimService.ProcessarIntegracao() in /src/Inpart.Integracao.GerenciadorJobs/Services/JobIntegradorAssimService.cs:line 524
   at InvokeStub_TaskAwaiter`1.GetResult(Object, Object, IntPtr*)
   at System.Reflection.RuntimeMethodInfo.Invoke(Object obj, BindingFlags invokeAttr, Binder binder, Object[] parameters, CultureInfo culture)

+26ms Processing

Server:
fe68b61060a9.staging:1
Worker:
a0b34e40

+28.640s Enqueued

Triggered by DelayedJobScheduler

+ <1ms Scheduled

Retry attempt 1 of 1: An error occurred while reading a database value …

Enqueue at:
10/09/2026 22:15:40

+4.017s Failed

An exception occurred during performance of the job.

System.Exception (fe68b61060a9.staging:1)

An error occurred while reading a database value for property 'NFItem.CdStatus'. The expected type was 'System.Int16' but the actual value was of type 'System.Byte'.

System.Exception: An error occurred while reading a database value for property 'NFItem.CdStatus'. The expected type was 'System.Int16' but the actual value was of type 'System.Byte'.
   at Inpart.Integracao.GerenciadorJobs.Services.JobIntegradorAssimService.ProcessarIntegracao() in /src/Inpart.Integracao.GerenciadorJobs/Services/JobIntegradorAssimService.cs:line 524
   at InvokeStub_TaskAwaiter`1.GetResult(Object, Object, IntPtr*)
   at System.Reflection.RuntimeMethodInfo.Invoke(Object obj, BindingFlags invokeAttr, Binder binder, Object[] parameters, CultureInfo culture)

+47ms Processing

Server:
fe68b61060a9.staging:1
Worker:
f5c0b0c0

+6ms Enqueued

Triggered by recurring job scheduler

10/09/2026 22:15:11 Created